1. No-load test: When there is no load, the forward rod and the reverse rod are reciprocated three times to observe the working condition of the mechanism, and there should be no jamming.
2. Rated load test: Tested on a special test bench, the hand pull force and the handle reciprocating once the wire rope stroke should meet the standard requirements.
3. Dynamic load test: Tested on a special test bench, loaded with 1.1 times rated load, rising and falling once, each wire rope moving distance shall not be less than 200mm, the whole machine shall work smoothly and reliably.
4. Static load test: On the special test bench, gradually load to 1.5 times the rated load and stay for 10 minutes. The clamp and clamping plate must not have permanent deformation that affects the performance.
5. Hook test:
On the material testing machine, gradually load to 2 times the rated load through the center of the hook cavity, and then remove the load after staying for 1 min, and check the hook port deformation of the hook, which should not exceed 0.25%;
On the material testing machine, the hook is gradually loaded to 4 times the rated load through the center of the hook cavity, and the hook should be able to reliably support 1 min.
Reliability test: Under the rated load, the forward and reverse rods are continuously reciprocated, so that the cumulative travel of the wire rope is not less than 120m (can be divided into four times, but each time, but the cumulative stroke of the wire rope is 30m each time, The interval between each time does not exceed 1 h. It is not allowed to replace the wire rope during the test). There shall be no abnormalities in the parts of the hoist.